Walk In Chamber
Introduction:
Walk in chamber is a kind of climate chamber. The main difference from the ordinary constant temperature and humidity test chamber is that Walk in chamber is suitable for large size or certain special equipment and technical methods to make its indoor temperature and humidity conform to the requirements of a certain humidity control and standard atmosphere for testing. Walk In chamber adopts intelligent control mode to realize the function of refrigerating, humidity test ,hot and cold temperature test, temperature and humidity test of the unit, so as to control the temperature and humidity of the indoor environment accurately. Walk in chamber mainly used in textile testing system, paper detection, metrology calibration, coating testing, packaging testing, precision machining, three coordinate testing, research institutions, etc.
Test standard(including but not limited to… ):
Compliance with ASTM G53-77 specifications GB, GJB, MIL, ASTM, CNS, IEC, JIS, AATCC, DIN, Fed Test, BS and SAE.
Specification:
- temperature range -50c to +100c
- humidity range 40% to 98% rh
- dimension (internal) (w x d x h) 1500 x 1500 x 3000 mm
- dimension (external) (w x d x h) 2850 x 1700 x 3200 mm
- ramp variable, temp. 0~5c / min & humidity 0~5%/min in average, no load
- accuracy temp. ±1c, humidity ±2.5%rh
- interior walls stainless steel 304
- exterior walls cold rolled stell plate with baking finish
- temperature & humidity measurement and controller 32 bit control and monitoring system. interface facility with rs232 programmable temp. humid. controller
- viewing window multi pane glass window size
- port holes 50 mm diameter for wire routing
- power supply requirement three phase, ac380 v ± 10 %, 50 hz
- sound pressure level<72db (a)
- condenser cooling water cooled
General Technical Specification
Thermal cyclic chamber
chamber with internal air circulation, and all the heaters and cooling coil located behind/below the false.sheet of the chamber and outside the working space
Interior
the conditioning with air circulation to maintain uniform temperature
interior have provision for arranging stainless steel
Insulation
insulation is asbestos-free csc-free, with low thermal conductivity, polyrthene pu foam
Cooling System
cascade type, refrigeration system with hermetically sealed refrigeration ,cycles with environment and ozone friendly and chloride free refrigeration
Door
lockable front opening, with double door latch easy to open
with silicon gasket for perfect sealing
Viewing Window
viewing interlock is sealed to avoid leakage and provided with heating provision to prevent condensation
Illumination
inernallight on viewing windows with external control
Temperature measuring and control system
the temperature measuring and control system adopts microprocessor system and provided with touch ,panel for monitoring and digital display:
Supplied with support software
software is capable to visualize and graphical anallyse the measured & recorded value.
graphical representation and digital display and control of set and actual values
digital input and display of temperature in degree centigrade
fault diagnosis system
120 stroage of programmes
have adjustable safety cut-out against high and low temperature
facility to programme temperature measuring using sensor pt100
recorder & pc connectivity
standard rs -232 interface for pc connectivity
rs-232 cable for pc connectivity along with pc connectivity software
port holes
each port hole provided with silicon sealing bunker (plug)
electrical panel
all power connectors, protection devices power control logic built in the control panel integrated to the chamber
all electrical cables tagged with id number
all electrical function circuit equipped with its own safety device that shuts down the relevant circuit or the entire test chamber if a faulty develops
all electrical systems comply with recognized technical regulation as well as with the accident prevention regulations.
standard protection
protective feature to be provided as follows:
- over load trip & earth leakage trip for complete chamber
- over load trip for compressors, heaters and motors
- over temperature cut-off for compressors
- heater be cut off, if air circulation blowers are off
operating system
detailed operating & maintanance manual
- operational instruction
- complete list parts
- preventive maintenance procedure
- trouble shooting measures
- electrical circuit diagrams
testing sample
solor panels, size 2mh * 1mw * 1md, size 2mh * 1mw * 1md